{"id":548,"date":"2016-10-06T12:28:31","date_gmt":"2016-10-06T10:28:31","guid":{"rendered":"https:\/\/www.f3dm.de\/?page_id=548"},"modified":"2023-03-10T13:13:04","modified_gmt":"2023-03-10T11:13:04","slug":"x-ray-tomography","status":"publish","type":"page","link":"https:\/\/www.f3dm.de\/en\/x-ray-tomography\/","title":{"rendered":"Computer tomography"},"content":{"rendered":"\n<div class=\"wp-block-impuls-additional-containers-impulsbgcontainer  has-no-text-color has-light-gray-background-color has-background-color has-background-image\" style=\"background-image:url(https:\/\/www.f3dm.de\/wp-content\/uploads\/2018\/12\/linien_01.png)\"><div class=\"InnerContent\">\n<h2 class=\"wp-block-heading\">Industrial computed tomography<\/h2>\n\n\n\n<div class=\"wp-block-columns has-2-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>Imaging by means of computed\ntomography enables non-destructive testing and measurement of areas of\ncomponents, assembled assemblies or even composite components that are not\naccessible at all or only to a limited extent.<\/p>\n\n\n\n<p>In contrast to all other scanning\nmethods, a component or assembly group can be recorded in its entirety, thus\noffering a much wider range of evaluation options.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"483\" src=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/gVolumendaten-auswerten_Autoscheinwerfer-1024x483-1024x483.png\" alt=\"\" class=\"wp-image-2583\" srcset=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/gVolumendaten-auswerten_Autoscheinwerfer-1024x483.png 1024w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/gVolumendaten-auswerten_Autoscheinwerfer-1024x483-300x142.png 300w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/gVolumendaten-auswerten_Autoscheinwerfer-1024x483-768x362.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-impuls-additional-containers-impulsbgcontainer  has-no-text-color has-light-gray-background-color has-background-color has-background-image\" style=\"background-image:url(https:\/\/www.f3dm.de\/wp-content\/uploads\/2018\/12\/linien_01.png)\"><div class=\"InnerContent\">\n<div class=\"wp-block-columns has-2-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"458\" src=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2016\/10\/ct09-1024x458.png\" alt=\"\" class=\"wp-image-1096\" srcset=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2016\/10\/ct09-1024x458.png 1024w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2016\/10\/ct09-300x134.png 300w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2016\/10\/ct09-768x343.png 768w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2016\/10\/ct09.png 1248w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>In addition to the classic\nevaluations of dimensions, shape and layers, this also enables analyses of the\nmaterial structure such as:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>porosity \/ inclusion detection (Lunker analysis)<\/li>\n\n\n\n<li>False color matches\/comparisons<\/li>\n\n\n\n<li>Aging analyses<\/li>\n\n\n\n<li>Target\/actual comparisons<\/li>\n\n\n\n<li>Initial sample measurements \/ First sampling (FAIR)<\/li>\n\n\n\n<li>Defect analyses<\/li>\n\n\n\n<li>Reverse engineering<\/li>\n<\/ul>\n\n\n\n<p><\/p>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-impuls-additional-containers-impulsbgcontainer  has-no-text-color has-light-gray-background-color has-background-color has-background-image\" style=\"background-image:url(https:\/\/www.f3dm.de\/wp-content\/uploads\/2018\/12\/linien_01.png)\"><div class=\"InnerContent\">\n<div class=\"wp-block-columns has-2-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>For computer tomography or X-ray\ntomography, we use a modern Werth TomoScope L300 in our company. Depending on\nthe customer&#8217;s requirements and the nature of the part to be inspected, a power\nof up to 300 kV is possible.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Computer tomograph<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Manufacturer:<\/td><td>Werth<\/td><\/tr><tr><td>Max. Workpiece gr..e:<\/td><td>D = 470 mm \/ L = 678 mm (depending on the aspect ratio of the workpieces, more if necessary)<\/td><\/tr><tr><td>Accuracy:<\/td><td>4,5 \u03bcm \u2013 0,02 mm<\/td><\/tr><tr><td>Calibration:<\/td><td>Standard-compliant calibration according to VDI 2617 with DAkkS certificate<\/td><\/tr><tr><td>Special features:<\/td><td>considerable time saving due to patented stepless rotary axis<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/11\/2d-soll-ist.png\" alt=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/11\/2d-soll-ist.png\" class=\"wp-image-2345\" srcset=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/11\/2d-soll-ist.png 600w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/11\/2d-soll-ist-150x150.png 150w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/11\/2d-soll-ist-300x300.png 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-impuls-additional-containers-impulsbgcontainer  has-no-text-color has-light-gray-background-color has-background-color has-background-image\" style=\"background-image:url(https:\/\/www.f3dm.de\/wp-content\/uploads\/2018\/12\/linien_01.png)\"><div class=\"InnerContent\">\n<h3 class=\"wp-block-heading\">Application examples<\/h3>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-2 is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Automatische-Graterkennung.png\" data-lbwps-width=\"2126\" data-lbwps-height=\"1308\" data-lbwps-srcsmall=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Automatische-Graterkennung-300x185.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"630\" data-id=\"2508\" src=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Automatische-Graterkennung-1024x630.png\" alt=\"\" class=\"wp-image-2508\" srcset=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Automatische-Graterkennung-1024x630.png 1024w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Automatische-Graterkennung-300x185.png 300w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Automatische-Graterkennung-768x473.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/plato.png\" data-lbwps-width=\"2124\" data-lbwps-height=\"1535\" data-lbwps-srcsmall=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/plato-300x217.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"740\" data-id=\"2509\" src=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/plato-1024x740.png\" alt=\"\" class=\"wp-image-2509\" srcset=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/plato-1024x740.png 1024w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/plato-300x217.png 300w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/plato-768x555.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Punktewolken-auswerten.png\" data-lbwps-width=\"1287\" data-lbwps-height=\"732\" data-lbwps-srcsmall=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Punktewolken-auswerten-300x171.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"582\" data-id=\"2510\" src=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Punktewolken-auswerten-1024x582.png\" alt=\"Punktewolken auswerten\" class=\"wp-image-2510\" srcset=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Punktewolken-auswerten-1024x582.png 1024w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Punktewolken-auswerten-300x171.png 300w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Punktewolken-auswerten-768x437.png 768w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Punktewolken-auswerten.png 1287w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Zwei-Spektren-Tomografie.png\" data-lbwps-width=\"1122\" data-lbwps-height=\"507\" data-lbwps-srcsmall=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Zwei-Spektren-Tomografie-300x136.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"463\" data-id=\"2511\" src=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Zwei-Spektren-Tomografie-1024x463.png\" alt=\"Zwei-Spektren-Tomografie\" class=\"wp-image-2511\" srcset=\"https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Zwei-Spektren-Tomografie-1024x463.png 1024w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Zwei-Spektren-Tomografie-300x136.png 300w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Zwei-Spektren-Tomografie-768x347.png 768w, https:\/\/www.f3dm.de\/wp-content\/uploads\/2022\/12\/Zwei-Spektren-Tomografie.png 1122w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n<\/figure>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Interconnected and complex components or specific materials are measured by laser, X-rays or camera-assisted systems.<\/p>\n","protected":false},"author":2,"featured_media":2411,"parent":0,"menu_order":90,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-548","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.f3dm.de\/en\/wp-json\/wp\/v2\/pages\/548","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.f3dm.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.f3dm.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.f3dm.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.f3dm.de\/en\/wp-json\/wp\/v2\/comments?post=548"}],"version-history":[{"count":81,"href":"https:\/\/www.f3dm.de\/en\/wp-json\/wp\/v2\/pages\/548\/revisions"}],"predecessor-version":[{"id":3200,"href":"https:\/\/www.f3dm.de\/en\/wp-json\/wp\/v2\/pages\/548\/revisions\/3200"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.f3dm.de\/en\/wp-json\/wp\/v2\/media\/2411"}],"wp:attachment":[{"href":"https:\/\/www.f3dm.de\/en\/wp-json\/wp\/v2\/media?parent=548"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}